introduction The maximum depth allowable for a T-Riser is dictated by the strength of the supporting pipe section, which is typically a Class V pipe, though special design (i.e. SIDD) can be accommodated if necessary. Similarly, the bedding and installation procedures for a T-Riser manhole are the same as for a standard piece of concrete pipe. A T-Riser is manufactured using two separate pieces; a concrete pipe and manhole barrel. Each piece is scarred to expose their reinforcement before the pieces are welded together and further reinforced. After the two pieces have been joined, a concrete collar is poured around the reinforcement to create a cold joint. More recent manufacturing processes see the manhole barrel wetcast over the pipe using a specialized “saddle” form. Please contact your local Lafarge Pipe representative for more information on T-Riser assembly, availability, and production schedules. concrete pipe stormwater treatment technologies Refer to your local Lafarge Concrete Pipe product catalogue for dimensional information on the T-Risers available in your area. introduction CONCRETE PIPE CONCRETE PIPE concrete pipe Providing high quality precast concrete drainage materials across Western Canada. box sections For information on pipe design, including maximum allowable depths and direct design alternatives, please refer to the Concrete Pipe section of this eManual. stormwater treatment technologies LAFARGE PIPE 6920 13 Street SE Calgary, AB T2H3B1 Tel. (403) 292-9501 Fax: (403) 255-2677 box sections www.lafarge-na.com/pipe manhole and catch basin material LAFARGE PIPE eMANUAL PAGE 9 manhole and catch basin material LAFARGE PIPE eMANUAL PAGE 47